Chinese Journal of Nursing ›› 2025, Vol. 60 ›› Issue (13): 1553-1557.DOI: 10.3761/j.issn.0254-1769.2025.13.003

• Intravenous Therapy Practice and Management • Previous Articles     Next Articles

Application of f-wave to QRS complex amplitude ratio in PICC tip positioning for patients with atrial fibrillation

SHI Lihua(), YANG Rongrong, LIAO Lihong, GUO Jing, SUN Qiu, GONG Yuanyuan, YE Jiabao, ZHANG Jianfang()   

  • Received:2024-08-14 Online:2025-07-10 Published:2025-07-03
  • Contact: ZHANG Jianfang

f波与QRS波振幅比值在房颤患者PICC尖端定位中的应用研究

施丽华(), 杨荣荣, 廖丽红, 郭菁, 孙秋, 贡源源, 叶加宝, 张建芳()   

  1. 215008 苏州市 南京医科大学附属苏州医院护理部(施丽华,张建芳),心血管病中心(杨荣荣,廖丽红,孙秋,贡源源,叶加宝),静脉治疗门诊(郭菁)
  • 通讯作者: 张建芳
  • 作者简介:施丽华:女,本科,副主任护师,E-mail:178632734@qq.com
  • 基金资助:
    中华护理杂志社2023年静脉治疗护理专项科研项目(ZHHLZZS-202311)

Abstract:

Objective To evaluate the clinical utility of the f-wave to QRS complex amplitude ratio(f/R ratio) in intracardiac electrogram(IC-ECG)-guided positioning of peripherally inserted central catheter(PICC) tips in patients with atrial fibrillation(AF),providing evidence to enhance clinical practice. Methods This study employed a convenience sampling method to enroll eligible AF patients admitted to a tertiary hospital in Suzhou from July 2023 to July 2024. During PICC placement,IC-ECG was utilized to monitor f-wave and QRS complex amplitude variations. Following successful catheterization,the f/R ratio was measured,and chest X-ray was performed to confirm the catheter tip position. The accuracy of PICC tip positioning across different f/R ratio ranges was analyzed,and the incidence of arrhythmias was recorded. A receiver operating characteristic curve was constructed to assess the diagnostic performance of the f/R ratio in PICC tip localization. Results A total of 68 AF patients were included,with f/R ratios ranging from 20.63% to 91.24%. PICC tip positioning accuracy varied significantly across different f/R ratio ranges(P=0.006). The area under the ROC curve(AUC) for f/R ratio in PICC tip positioning was 0.784(P=0.009),with a maximum Youden index of 0.567,an optimal diagnostic threshold of 40.00%,a sensitivity of 81.7%,a specificity of 75.0%,a positive predictive value of 96.1%,and a negative predictive value of 35.3%. No arrhythmias other than AF occurred during the procedure. Conclusion The f/R ratio provides reliable and safe guidance for PICC tip positioning in AF patients. An f/R ratio≥40% is associated with higher accuracy in identifying the optimal catheter tip position.

Key words: Atrial Fibrillation, Intracardiac Electrogram, Peripherally Inserted Central Catheter, Tip Positioning, Nursing Care

摘要:

目的 探讨f波与QRS波振幅的比值(以下简称f/R值)在房颤患者心腔内电图PICC尖端定位中的应用效果,以指导临床实践。方法 采用便利抽样法,选取2023年7月—2024年7月苏州市某三级甲等医院收治的房颤患者作为研究对象。在PICC置管过程中,连接心腔内电图并观察f波及QRS波振幅变化,置管成功后测量f/R值,并通过胸部X线确定导管尖端位置。比较不同范围f/R值对应的PICC尖端位置准确率,并收集心律失常发生率。绘制受试者操作特征曲线,分析f/R值在PICC尖端定位中的诊断价值。结果 共纳入68例房颤患者,f/R值为20.63%~91.24%。不同范围f/R值对应的PICC尖端位置准确率比较,差异具有统计学意义(P=0.006)。f/R值在PICC尖端定位中的受试者操作特征曲线下面积为0.784(P=0.009)、Youden指数最大值为0.567、最佳诊断临界值为40.00%、灵敏度为81.7%、特异度为75.0%、阳性预测值为96.1%、阴性预测值为35.3%。置管过程中,所有患者均未发生除房颤外的心律失常。结论 通过f/R值定位PICC尖端位置具有准确性和安全性,f/R值≥40%时判断PICC尖端位于理想位置的准确率较高。

关键词: 心房颤动, 心腔内电图, 经外周静脉穿刺中心静脉导管, 尖端定位, 护理