Design and application of loop stoma support rod device

WANG Qunmin(),WANG Feixia,CHEN Yehong,PAN Zhe,LI Weizhen,LI Xia,WANG Qin,SHENG Qinsong,ZHONG Zifeng()   

  • Received:2021-02-24 Online:2021-07-15 Published:2021-06-29
  • Contact: Zifeng ZHONG

襻式造口支撑棒装置的设计及应用

王群敏(),王飞霞,陈叶红,潘喆,李卫珍,李霞,王琴,盛勤松,钟紫凤()   

  1. 310003 杭州市 浙江大学医学院附属第一医院结直肠外科(王群敏,陈叶红,王琴,盛勤松),伤口、造口专科护士门诊部(王飞霞,潘喆,李卫珍,李霞),医院感染管理部(钟紫凤)
  • 通讯作者: 钟紫凤
  • 作者简介:王群敏:女,本科,副主任护师,护士长,E-mail: 1192051@zju.edu.cn
  • 基金资助:
    浙江省医药卫生技术成果项目(2018PY008)

Abstract:

Objective To design a loop stoma support rod device and to explore its application effect in stoma care. Methods The support rod device was self-designed and self-manufactured with 2 fixed wing hard films,2 fixed wing soft films and 1 support rod. Patients who were planned to undergo a loop stoma in a Level A tertiary hospital in Zhejiang Province from August 2019 to October 2020 were enrolled and randomized to 3 groups,namely the experimental group with a self-made loop stoma support rod device,the control group 1 and group 2 with traditional suture method and loop method respectively to fix the support tube. The general information of patients and caregivers,the operation time of nurses and caregivers to change stoma bag,the pain degree during the operation,the incidence of stoma and surroundings complications,and other indicators were compared between the 3 groups. Results There was no significant difference in the general information of patients and caregivers,and the operation time of nurses and caregivers among the 3 groups(P>0.05). The local pain degree scores of patients when nurses and caregivers replaced the stoma bags were(1.90±0.64) points and(1.33±0.83) points in the experimental group,(4.11±0.77)points and(4.21±0.64)points in the control group 1,(2.52±0.68)points and(2.63±0.60) points in the control group 2;there was statistically significant difference between the 3 groups(allP<0.05). The incidences of complications of patients with pressure injury,mucocutaneous separation,and peristomal dermatitis, were 0,3.23%,12.90% in the experimental group, 32.26%,32.26%,54.84% in the control group 1,and 20.00%,26.67%,40.00% in the control group 2;the differences were statistically significant(allP<0.05). Conclusion The self-designed loop stoma support rod device can effectively reduce the incidence of stoma and surroundings complications,reduce the local pain during nursing care,and improve patient’s comfort.

Key words: Ileostomy, Loop Stoma, Support Rod, Nursing Instrument, Perioperative Nursing

摘要:

目的 设计襻式造口支撑棒装置并探讨其在造口护理中的应用效果。 方法 自行设计和制作襻式造口支撑棒装置,该装置由2片固定翼硬片、2片固定翼软片、1根支撑棒棒体组成。选取2019年8月—2020年10月浙江省某三级甲等综合医院收治的拟行直肠肿瘤切除+回肠襻式造口手术的患者及其照顾者作为研究对象,将患者随机分为试验组、对照组1和对照组2,试验组采用自制的襻式造口支撑棒装置,对照组1和对照组2分别使用传统缝合法和环套法固定支撑管,比较3组的一般资料、护士和照护者更换造口袋操作时间、操作时患者的疼痛程度、造口相关并发症发生率等指标。 结果 3组的一般资料、护士和照护者更换造口袋操作时间比较,差异无统计学意义(P>0.05);护士和照护者更换造口袋操作时患者局部疼痛程度评分比较,试验组分别为(1.90±0.64)分、(1.33±0.83)分,对照组1分别为(4.11±0.77)分、(4.21±0.64)分,对照组2分别为(2.52±0.68)分、(2.63±0.60)分,3组比较,差异均有统计学意义(均P<0.001);患者压力性损伤、造口黏膜皮肤分离、造口周围皮炎并发症发生率比较,试验组分别为0、3.23%、12.90%,对照组1分别为32.26%、32.26%、54.84%,对照组2分别为20.00%、26.67%、40.00%,差异均有统计学意义(均P<0.05)。 结论 自行设计的襻式造口支撑棒装置应用于造口护理,能有效降低患者造口相关并发症的发生率,减轻护理时局部的疼痛程度,提高患者的舒适度。