10例左心室辅助装置植入患者使用氯己定消毒致皮肤过敏的护理

张艳明1,*(), 金琰2, 王现强1   

  1. 1 中国医学科学院阜外医院成人心外科五病区 北京市 100037
    2 中国医学科学院阜外医院重症监护室 北京市 100037
  • 收稿日期:2026-01-04 出版日期:2026-07-20 发布日期:2026-07-17
  • *通讯作者: 张艳明,女,本科,副主任护师,E-mail:yangming7253@163.com
  • 作者简介:第一联系人:

    张艳明:研究设计、论文撰写及修改、经费支持;金琰:实施研究、采集数据;王现强:论文审校及修订

  • 基金资助:
    中国医学科学院阜外医院护理部专项基金(HLZX2024012)

Nursing care of 10 patients with skin allergy caused by chlorhexidine disinfectant after implantation of left ventricular assist device

ZHANG Yanming1,*(), JIN Yan2, WANG Xianqiang1   

  1. 1 Department of Adult Surgery Ward 5Fuwai Hospital,Chinese Academy of Medical SciencesBeijing 100037, China
    2 Department of Intensive Care UnitFuwai Hospital,Chinese Academy of Medical SciencesBeijing 100037, China
  • Received:2026-01-04 Online:2026-07-20 Published:2026-07-17
  • * Corresponding author: ZHANG Yanming,E-mail:yangming7253@163.com
  • Funding program:
    Special Fund of the Nursing Department,Fuwai Hospital,Chinese Academy of Medical Sciences(HLZX2024012)

摘要:

总结10例左心室辅助装置植入术后患者线缆出口使用2%葡萄糖酸氯己定醇皮肤消毒液消毒后,皮肤出现不同程度过敏及继发线缆出口感染的护理经验。护理要点:正确识别氯己定消毒液过敏症状,及早进行对症护理;加强皮肤护理,预防线缆出口感染或感染加重;做好患者和家属的健康教育及培训,提升过敏自我监测及管理能力。经过精心的治疗及护理,随访6~30周,7例未再发生过敏,3例继发线缆出口感染,经治疗和护理后好转,未再发生过敏。

关键词: 左心室辅助装置, 线缆出口皮肤管理, 氯己定过敏, 护理

Abstract:

This article summarizes the nursing experience of 10 patients with post-left ventricular assist device (LVAD) implantation,where skin allergic reactions of varying degrees and associated cable exit infections occurred after disinfection of the cable exit with 2% chlorhexidine gluconate. Key nursing points:accurately identifying allergic reactions to chlorhexidine disinfectant and providing timely symptomatic care;enhancing skin care to prevent or mitigate infections at the catheter insertion site;conducting thorough patient and family education and training to improve self-monitoring and management of allergic reactions. Through meticulous treatment and nursing care,with follow-up periods ranging from 6 to 30 weeks,7 patients did not experience recurrence of allergies,and 3 cases of secondary infection at the cable exit site showed improvement after treatment and nursing care,with no recurrence of allergic reactions.

Key words: Left Ventricular Assist Device, Cable Exit Skin Management, Chlorhexidine Allergy, Nursing Care