中华护理杂志 ›› 2022, Vol. 57 ›› Issue (7): 823-826.DOI: 10.3761/j.issn.0254-1769.2022.07.009

• 专科实践与研究 • 上一篇    下一篇

儿童静脉输液过程质量监控数据表的构建及应用

黄勤(), 张晓波(), 顾莺, 胡静, 孔梅婧, 傅唯佳   

  1. 201102 上海市 复旦大学附属儿科医院护理部(黄勤,顾莺,胡静,孔梅婧),院办(张晓波),信息科(傅唯佳)
  • 收稿日期:2021-09-27 出版日期:2022-04-10 发布日期:2022-03-31
  • 通讯作者: 张晓波,E-mail: Zhangxiaobo0307@163.com
  • 作者简介:黄勤:女,本科,副主任护师,护理部主任助理,E-mail: huangqin2005@aliyun.com
  • 基金资助:
    上海市卫生健康委员会智慧医疗专项研究项目(2018ZHYL0225)

Development and application of a data table system for monitoring the quality of pediatric intravenous infusion process

HUANG Qin(), ZHANG Xiaobo(), GU Ying, HU Jing, KONG Meijing, FU Weijia   

  • Received:2021-09-27 Online:2022-04-10 Published:2022-03-31

摘要:

目的 构建儿童静脉输液过程质量监控数据表并评价其临床应用效果。方法 根据静脉输液操作流程,形成静脉输液执行、巡查2项过程质量监控数据表,实现静脉输液全流程质量监控。于2020年12月在上海市某三级甲等儿科医院正式运行数据表,比较数据表应用后(2021年3月—4月)与试运行阶段(2020年10月—11月)的静脉输液执行移动护理终端(personal digital assistant,PDA)扫描率、静脉输液结束PDA扫描率、静脉输液巡查次数合格率、静脉输液巡查时间准确率;采用临床护理信息系统有效性评价量表,评价护理管理人员对该数据表的满意度。结果与试运行阶段相比,数据表应用后静脉输液执行PDA扫描率由96.76%上升到99.96%,静脉输液结束PDA扫描率由97.88%上升到98.82%,静脉输液巡查次数合格率由57.96%上升到66.85%,静脉输液巡查时间准确率由95.68%上升到96.79%,差异均具有统计学意义(P<0.001);护理管理人员对该数据表的满意度评分为(95.25±0.08)分。结论 借助儿童静脉输液过程质量监控数据表,护理管理人员可充分利用临床数据,规范临床护理人员的行为,持续改进儿童静脉输液的过程质量;护理管理人员对该数据表的满意度较高。

关键词: 静脉输液, 过程质量, 数据表, 护理管理研究, 儿科护理学

Abstract:

Objective To develop a data table system for monitoring the quality of pediatric intravenous infusion process and to evaluate its clinical effectiveness. Methods The data table system was designed to monitor the whole process of intravenous infusion by automatically capturing data from administration,inspection to completion,followed by the generation of personal digital assistant(PDA) scan identification data table and infusion inspection data table. The data table system was put into use since December,2020 in a tertiary children’s hospital in Shanghai. Data collected from October to November,2020 were compared with that from March to April,2021 in terms of PDA scanning rates at the beginning and end of intravenous administration,qualified rate of the number of intravenous infusion inspection,and accuracy rate of intravenous infusion inspection timing. The Effectiveness Evaluation Scale of Clinical Nursing Information System was used to evaluate nursing managers’ satisfaction. Results The PDA scanning rate at the beginning of intravenous administration was improved from 96.76% to 99.96%(P<0.001);the PDA scanning rate at the end of intravenous administration was improved from 97.88% to 98.82%(P<0.001);the qualified rate of the number of intravenous infusion inspection was improved from 57.96% to 66.85%(P<0.001);the accuracy of intravenous infusion inspection time was improved from 95.68% to 96.79%(P<0.001). The satisfaction score of nursing managers with the data table system was(95.25±0.08). Conclusion The development of the data table system could help nursing management departments facilitate the use of the clinical data in order to continuously improve the nursing quality and nurses’ behavior. With the help of information service,the data table system for monitoring nursing quality provided a better user experience.

Key words: Intravenous Infusion, Process Quality, Data Table, Nursing Administration Research, Pediatric Nursing