| [1] |
胥焕, 杨春燕, 许平. 出生体重<1500g早产儿静脉营养疗效及并发症观察[J]. 中华危重病急救医学, 2019, 31(11):1395-1400.
|
|
Xu H, Yang CY, Xu P. Observation on the efficacy and complications of intravenous nutrition for premature infants with birth weight<1500g[J]. Chin Crit Care Med, 2019, 31(11):1395-1400.
|
| [2] |
Bashir RA, Callejas AM, Osiovich HC, et al. Percutaneously inserted central catheter-related pleural effusion in a level Ⅲneonatal intensive care unit:a 5-year review(2008-2012)[J]. JPEN J Parenter Enteral Nutr, 2017, 41(7):1234-1239.
DOI
PMID
|
| [3] |
范歆颀. 新生儿PICC导管继发性异位的临床特点及研究进展[J]. 中华急危重症护理杂志, 2020, 1(5):463-467.
|
|
Fan XQ. Clinical characteristics and research progress of secondary malposition of peripherally inserted central venous catheter in neonates[J]. Chin J Emerg Crit Care Nurs, 2020, 1(5):463-467.
|
| [4] |
Sertic AJ, Connolly BL, Temple MJ, et al. Perforations associated with peripherally inserted central catheters in a neonatal population[J]. Pediatr Radiol, 2018, 48(1):109-119.
DOI
PMID
|
| [5] |
Zarkesh MR, Haghjoo M. Neonatal cardiac tamponade,a life-threatening complication secondary to peripherally inserted central catheter:a case report[J]. J Med Case Rep, 2022, 16(1):305.
|
| [6] |
陈晓春, 陈琼, 童燕芬, 等. 新生儿PICC尖端异位与自发矫正情况分析[J]. 中华护理杂志, 2019, 54(4):558-561.
DOI
|
|
Chen XC, Chen Q, Tong YF, et al. Tip malposition and spontaneous correction of peripherally inserted central catheters among neonates[J]. Chin J Nurs, 2019, 54(4):558-561.
DOI
|
| [7] |
胡艳玲, 唐孟言, 李小文, 等. 新生儿PICC导管异位影响因素及预防措施的研究进展[J]. 护理学杂志, 2020, 35(22):105-108.
|
|
Hu YL, Tang MY, Li XW, et al. A review of associated factors regarding malposition of neonatal peripherally inserted central venous catheter:nursing interventions[J]. J Nurs Sci, 2020, 35(22):105-108.
|
| [8] |
沈婷, 余婷, 聂玲, 等. 新生儿PICC导管尖端继发性异位预防和处理的最佳证据总结[J]. 中华护理杂志, 2023, 58(18):2273-2281.
DOI
|
|
Shen T, Yu T, Nie L, et al. Summary of the best evidence for the prevention and management of PICC secondary catheter tip malposition in neonates[J]. Chin J Nurs, 2023, 58(18):2273-2281.
DOI
|
| [9] |
Sharpe EL. Repositioning techniques for malpositioned neonatal peripherally inserted central catheters[J]. Adv Neonatal Care, 2010, 10(3):129-132.
DOI
PMID
|
| [10] |
左莉莉, 任义梅, 周洁, 等. 超声引导在极低/超低出生体重儿经外周中心静脉置管中的应用[J]. 中华新生儿科杂志(中英文), 2021, 36(5):20-23.
|
|
Zuo LL, Ren YM, Zhou J, et al. Application of ultrasound-guided peripherally inserted central catheter in very/extremely low birth weight infants[J]. Chin J Neonatol, 2021, 36(5):20-23.
|
| [11] |
刘燕. 关节量角器示值误差测量不确定度评定[J]. 中国计量, 2024(5):145-147.
|
|
Liu Y. Evaluation of uncertainty in measurement of indication error of joint protractor[J]. China Metrol, 2024(5):145-147.
|
| [12] |
冯立春, 冯永利, 王宝中, 等. 面向肩关节康复设备的研究进展[J]. 机械传动, 2024, 48(7):167-176.
|
|
Feng LC, Feng YL, Wang BZ, et al. Research progress of shoulder joint rehabilitation equipment[J]. J Mech Transm, 2024, 48(7):167-176.
|
| [13] |
杨明玉, 于丽, 程艳爽, 等. 四个极限体位对PICC尖端位置改变的影响[J]. 中华现代护理杂志, 2016, 22(11):1546-1548.
|
|
Yang MY, Yu L, Cheng YS, et al. Impact of four kinds of limit body position to PICC catheter tip position[J]. Chin J Mod Nurs, 2016, 22(11):1546-1548.
|
| [14] |
Ullman AJ, Chopra V, Brown E, et al. Developing appropriateness criteria for pediatric vascular access[J]. Pediatrics, 2020, 145(Suppl 3):S233-S242.
|
| [15] |
Lu YY, Hao CY, He WB, et al. Experimental research on pre-venting mechanical phlebitis arising from indwelling needles in intravenous therapy by external application of mirabilite[J]. Exp Ther Med, 2018, 15(1):276-282.
|
| [16] |
中华护理学会静脉输液治疗专业委员会. 静脉导管常见并发症临床护理实践指南[J]. 中华现代护理杂志, 2022, 28(18):2381-2395.
|
|
Chinese Nursing Association of Intravenous Infusion Therapy Specialized Committee. Clinical nursing practice guidelines for common complications of intravenous catheters[J]. Chin J Mod Nurs, 2022, 28(18):2381-2395.
|
| [17] |
Doyle SC, Bergin NM, Young R, et al. Diagnostic accuracy of ultrasound for localising peripherally inserted central catheter tips in infants in the neonatal intensive care unit:a systematic review and meta-analysis[J]. Pediatr Radiol, 2022, 52(12):2421-2430.
|
| [18] |
刘金明, 赖玉娥, 唐英姿, 等. 床旁B超动态定位技术在极早产儿PICC中的应用[J]. 华夏医学, 2023, 36(5):173-178.
|
|
Liu JM, Lai YE, Tang YZ, et al. Application of bedside B-mode ultrasound dynamic localization technique in PICC placement for extremely preterm infants[J]. Acta Med Sin, 2023, 36(5):173-178.
|
| [19] |
Hanks J, Myers B. Validity,reliability,and efficiency of a standard goniometer,medical inclinometer,and builder’s inclinometer[J]. Int J Sports Phys Ther, 2023, 18(4):989-996.
DOI
PMID
|
| [20] |
罗飞翔, 陈朔晖, 程晓英, 等. 极低出生体重儿PICC尖端位置与体重增长的相关性分析[J]. 中华护理杂志, 2017, 52(8):949-953.
|
|
Luo FX, Chen SH, Cheng XY, et al. A correlation analysis of PICC tip position and weight gaining in very low birth weight infants[J]. Chin J Nurs, 2017, 52(8):949-953.
|
| [21] |
黄学良, 杜小群. 探讨床旁超声心动图导管尖端定位在减少新生儿PICC置管异位中的应用[J]. 妇幼护理, 2024, 4(7):1759-1761.
|
|
Huang XL, Du XQ. Application of bedside echocardiographic catheter tip localization in reducing the occurrence of PICC catheter misplacement in neonates[J]. J Matern Child Nurs, 2024, 4(7):1759-1761.
|
| [22] |
Pires ABM, Lima AFC. Direct cost of peripheral catheterization by nurses[J]. Rev Bras Enferm, 2019, 72(1):88-94.
DOI
PMID
|
| [23] |
Beleza LO, Brasil GDC, Margatho AS, et al. Prevention of complications related to peripherally inserted central catheter insertion techniques in newborns:systematic review and network meta-analysis[J]. Rev Lat Am Enfermagem, 2024, 32:e4161.
|